Approved Document E and Sound Testing Explained

Short answer

Approved Document E gives the sound insulation standards for walls and floors separating dwellings in England. It applies to new homes and to material changes of use such as converting houses into flats. Pre-completion sound testing is normally required to show separating walls and floors meet minimum airborne and impact values. Conversions have slightly lower targets than new builds. Poor detailing and flanking are the main reasons tests fail.

Approved Document E and Sound Testing Explained

What Approved Document E covers

Approved Document E is the government guidance supporting Part E of the Building Regulations in England, which deals with resistance to the passage of sound. It sets out how separating walls and floors between dwellings, and between dwellings and other parts of a building such as common stairs, should limit sound transmission. It also covers internal walls and floors within new homes, and acoustic conditions in common areas and schools.

Wales has its own version of Approved Document E. In Scotland, sound insulation is covered by Section 5 (Noise) of the Building Standards Technical Handbooks, and conversions generally need a building warrant.

When it applies

The requirements apply to building work and material changes of use, not to upgrades you make to an existing home for your own comfort.

  • New build houses and flats with separating walls or floors
  • Converting a house into flats
  • Converting a commercial or other building into dwellings
  • Creating rooms for residential purposes, such as in student accommodation
  • Internal walls around bedrooms and bathrooms in new dwellings

The performance standards

Approved Document E sets minimum airborne sound insulation values, where higher is better, and maximum impact sound transmission values for floors, where lower is better. The values differ between new build and conversions, recognising that existing buildings are harder to bring up to standard. Airborne performance is measured as DnT,w plus Ctr in decibels. Impact performance is measured as L'nT,w in decibels.

ElementNew build dwellingsMaterial change of use
Separating wall, airborneAt least 45 dBAt least 43 dB
Separating floor, airborneAt least 45 dBAt least 43 dB
Separating floor, impactNo more than 62 dBNo more than 64 dB

How pre-completion testing works

Sound testing is carried out on site once the walls and floors are complete, ideally before final decoration but with doors and windows fitted. A tester places a loudspeaker in one room and measures sound levels in the room on the other side of the separating wall or floor. For impact tests, a standard tapping machine is placed on the floor above and levels are measured below. The results are corrected for room size and background noise, and compared with the required values.

Tests are carried out on a sample of separating walls and floors from each type of construction. If a test fails, remedial work is needed and the element retested. On new builds, using Robust Details registered constructions can be an alternative to testing, but for conversions testing is normally required.

Why conversions fail sound tests

Most failures come down to detailing rather than the choice of system. Common causes include gaps at the junction of a new ceiling and the original walls, unsealed services passing through the separating floor, recessed downlights in the ceiling, and floor voids that run continuously under a separating wall. In older buildings, original timber floors and lath and plaster ceilings provide very little mass, so they need full upgrading rather than a token layer of board.

Flanking through the external walls and shared chimney breasts is another frequent problem. Even if the floor itself is well built, sound can pass round it through the structure.

How to give yourself the best chance of passing

Plan acoustic detailing at design stage rather than leaving it to the end. Use proven systems from board and insulation manufacturers, built exactly as specified. Fill joist voids with acoustic mineral wool, isolate new ceilings, add resilient floor layers, use two layers of dense board, and seal every edge with acoustic sealant. Box in service penetrations and avoid recessed downlights in separating ceilings unless suitable acoustic hoods are used.

A specialist installer can also carry out a pre-test inspection, looking for gaps and bridging before the tester arrives. Fixing a missed detail at that stage is far cheaper than remedial work after a failed test, which may involve taking down finished ceilings.

Internal walls and floors in new homes

Part E also includes a requirement for internal walls and floors within new dwellings, not just between them. Walls around bedrooms and rooms containing a WC, and floors between storeys in a new house, should achieve a laboratory sound insulation rating of at least 40 dB Rw. This is shown by using constructions with suitable test data rather than by site testing. Typical solutions include stud walls with acoustic mineral wool in the cavity and floors with insulation between joists.

This requirement does not apply to conversions in the same way, and it does not cover walls containing doors. For developers, the practical point is to specify insulated partitions from the start, because adding insulation to finished stud walls means stripping one side. For homeowners buying a new build, it explains why internal walls are usually filled rather than hollow, and why a bedroom next to a bathroom should be quieter than in many older homes. If you are not sure whether a wall needs to meet this requirement, ask your building control body before the partitions are boarded.

Questions people also ask

Do I need sound testing for a house conversion into flats?

In England, yes in most cases. A material change of use to create flats brings the separating walls and floors under Approved Document E, and pre-completion sound testing is normally required to show they meet the minimum values. Building control will usually ask for the test results before signing off the work.

What sound insulation is needed between flats in a conversion?

For a material change of use in England, separating walls and floors should achieve at least 43 dB airborne sound insulation, measured as DnT,w plus Ctr, and floors should achieve impact sound transmission of no more than 64 dB, measured as L'nT,w. New builds have stricter targets of 45 dB and 62 dB.

What happens if a sound test fails?

Remedial work is needed to improve the failing wall or floor, and it must then be retested. Common fixes include sealing gaps, adding layers of board, isolating ceilings and treating flanking paths. Finding and fixing the specific weakness is cheaper than rebuilding, so a specialist survey is worthwhile.

Written and checked by the Soundproofing team. Read our editorial policy.